Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
J Dent ; 144: 104960, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513937

RESUMO

OBJECTIVES: The present study aims to examine the influence of the build angle on the accuracy (trueness and precision) of 3D printed crowns, table-tops and veneers with a hybrid resin-ceramic material. METHODS: One crown, on table-top and one veneer were printed in five different build angles (0°, 30°, 45°, 60°, 90°) (n = 50) with the digital light processing (DLP) system (Varseo XS, Bego) using hybrid resin (Varseo Smile Crownplus A3, Bego). All printed restorations were scanned using the laboratory scanner (D2000, 3Shape) and matched onto the initial reference design in metrology software (Geomagic Control X, 3D Systems). The root mean square error (RMSE) was calculated between the scanned and reference data. The data was statistically analyzed using the Tukey multiple comparison test and Wilcoxon multiple comparison test. RESULTS: The crown group showed higher trueness at 30° (0.021 ± 0.002) and 45° (0.020 ± 0.002), and table-tops at 0° (0.015 ± 0.001) and 30° (0.014 ± 0.001) (p < 0.0001). Veneers demonstrated higher trueness at 30° (0.016 ± 0.002) (p < 0.0001). All three restoration types demonstrated the lowest trueness at a 90° build angle and portrayed deviations along the z axis. The veneer and table-top groups showed the lowest precision at 90° (veneers: 0.021 ± 0.008; table-tops: 0.013 ± 0.003). The crown group portrayed the lowest precision at 45° (0.017 ± 0.005) (p < 0.0001). CONCLUSION: The build angle of DLP-printed hybrid resin-ceramic restorations influences their accuracy. CLINICAL SIGNIFICANCE: Considering the build angle is important to achieve a better accuracy of 3D-printed resin-ceramic hybrid restorations. This may help predict or avoid the interference points between a restoration and a die and minimize the clinical adjustments.


Assuntos
Cerâmica , Desenho Assistido por Computador , Coroas , Planejamento de Prótese Dentária , Facetas Dentárias , Impressão Tridimensional , Humanos , Planejamento de Prótese Dentária/métodos , Cerâmica/química , Propriedades de Superfície , Porcelana Dentária/química , Materiais Dentários/química , Processamento de Imagem Assistida por Computador/métodos , Teste de Materiais
2.
J Mech Behav Biomed Mater ; 152: 106458, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38364445

RESUMO

OBJECTIVES: To investigate the influence of material and printing orientation on wear resistance and flexural properties of one low force SLA- and two DLP-printed splint materials and to compare these 3D-printed splints to a subtractively manufactured splint material. METHODS: Two DLP-printed (V-Print splint, LuxaPrint Ortho Plus) and one low force SLA-printed (Dental LT Clear) material, where specimens were printed in three printing orientations (0°, 45°, 90°), were investigated. In addition, one milled splint material (Zirlux Splint Transparent) was examined. A total of 160 specimens were produced for both test series. The two-body wear test was performed in a chewing simulator (80'000 cycles at 50 N with 5-55 °C thermocycling). Steatite balls were used as antagonists. The wear pattern was analyzed with a 3D digital microscope in terms of maximum vertical intrusion depth (mm) and total volume loss (mm³). The flexural properties were investigated by three-point bending in accordance with ISO 20795-1: 2013 (denture base polymers). The flexural strength (MPa) and the flexural modulus (MPa) were measured. Two-way ANOVA was performed to investigate the effects of the two independent variables material and printing orientation for the three 3D-printed materials. The comparison of the printing orientations within one material was carried out with one-way ANOVA with post-hoc Tukey tests. RESULTS: Two-way ANOVA revealed that wear and flexural properties are highly dependent on the 3D-printed material (p < 0.001). Across groups, a significant effect was observed for wear depth (p = 0.031) and wear volume (p = 0.044) with regard to printing orientation but this was not found for flexural strength (p = 0.080) and flexural modulus (p = 0.136). One-way ANOVA showed that both DLP-printed groups showed no significant differences within the printing orientations in terms of wear and flexural properties. Dental LT Clear showed that 90° oriented specimens had higher flexural strength than 0° oriented ones (p < 0.001) and 45° oriented specimens also showed higher values than 0° ones (p = 0.038). No significant differences were observed within the printing orientations for flexural modulus and wear behaviour within this group. T-tests showed that the milled splints exhibited statistically higher wear resistance and flexural properties compared to all three 3D-printed splint materials (p < 0.001) and that highly significant differences were found between the 3D-printed splint materials for both test series. CONCLUSION: Within the limitations of this in vitro study, it can be stated that wear behaviour and flexural properties are highly dependent on the 3D-printed material itself. Currently, milled splints exhibit higher wear resistance and flexural properties compared to 3D-printed splint materials. The printing orientation has a minor influence on the properties investigated. Nevertheless, two-way ANOVA also showed a significant influence of printing orientation in the wear test across groups and one-way ANOVA detected significant effects for SLA material in terms of flexural strength, with printing in 90° showing the highest flexural strength. Therefore, anisotropy was found in SLA material, but it can be limited with the employed printing parameters. Both DLP-printed materials showed no significant difference within the printing orientation.


Assuntos
Resistência à Flexão , Gastrópodes , Animais , Contenções , Análise de Variância , Anisotropia , Impressão Tridimensional
3.
Nat Commun ; 15(1): 1534, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378748

RESUMO

Myotonic dystrophy type 2 (DM2) is a tetranucleotide CCTG repeat expansion disease associated with an increased prevalence of autoimmunity. Here, we identified an elevated type I interferon (IFN) signature in peripheral blood mononuclear cells and primary fibroblasts of DM2 patients as a trigger of chronic immune stimulation. Although RNA-repeat accumulation was prevalent in the cytosol of DM2-patient fibroblasts, type-I IFN release did not depend on innate RNA immune sensors but rather the DNA sensor cGAS and the prevalence of mitochondrial DNA (mtDNA) in the cytoplasm. Sublethal mtDNA release was promoted by a chronic activation of the ATF6 branch of the unfolded protein response (UPR) in reaction to RNA-repeat accumulation and non-AUG translated tetrapeptide expansion proteins. ATF6-dependent mtDNA release and resulting cGAS/STING activation could also be recapitulated in human THP-1 monocytes exposed to chronic endoplasmic reticulum (ER) stress. Altogether, our study demonstrates a novel mechanism by which large repeat expansions cause chronic endoplasmic reticulum stress and associated mtDNA leakage. This mtDNA is, in turn, sensed by the cGAS/STING pathway and induces a type-I IFN response predisposing to autoimmunity. Elucidating this pathway reveals new potential therapeutic targets for autoimmune disorders associated with repeat expansion diseases.


Assuntos
Doenças Autoimunes , Interferon Tipo I , Distrofia Miotônica , Humanos , Distrofia Miotônica/genética , Distrofia Miotônica/metabolismo , DNA Mitocondrial/genética , Autoimunidade/genética , Leucócitos Mononucleares/metabolismo , RNA , Nucleotidiltransferases/genética , Nucleotidiltransferases/metabolismo , Estresse do Retículo Endoplasmático/genética
4.
J Dent ; 142: 104832, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38211687

RESUMO

OBJECTIVES: The aim of this study was to evaluate the amount of enamel tooth wear induced by different antagonistic ceramic crown materials in the posterior area within a follow-up period up to 24 months in function. A network meta-analysis was performed to assess the effect of the materials on the mean vertical loss (MVL) of the antagonist enamel tooth surface. DATA: Main search terms used in combination: ceramic, dental materials, metal ceramic, tooth wear and dental enamel. SOURCES: An electronic search was conducted in PubMed/Medline, Embase, and Cochrane CENTRAL plus hand-searching. STUDY SELECTION: Eligibility criteria included clinical studies reporting on MVL on antagonist's tooth up to 24 months following the permanent crown placement. From a total of 5697 articles, 7 studies reporting on 261 crowns for 177 subjects with 3 ceramic materials (Lithium disilicate, metal-ceramic, monolithic zirconia) were included. Among all, metal-ceramic and zirconia caused significantly higher enamel tooth wear on antagonist teeth, representing 82.5 µm [54.4; 110.6]) and 40.1 µm [22.2; 58.0]) more MVL than natural teeth group. In contrast, lithium disilicate showed only 5.0 µm [-48.2; 58.1]) more MVL than occurs on opposing natural teeth. CONCLUSIONS: This systematic review demonstrated that prosthodontic ceramic materials produced significantly more antagonist enamel tooth wear than opposing natural enamel tooth wear, and ceramic material type was correlated to the degree of enamel tooth wear. Additional well-conducted, randomized controlled trials with homogeneous specimens are required due to inadequate sample size and number of the clinical studies included in the analyses. CLINICAL SIGNIFICANCE: The amount of wear caused by different restorative materials has a high influence on the antagonistic natural teeth and should therefore be evaluated intensively by the dentist.


Assuntos
Esmalte Dentário , Desgaste dos Dentes , Humanos , Cerâmica/efeitos adversos , Coroas , Porcelana Dentária/efeitos adversos , Desgaste de Restauração Dentária , Teste de Materiais , Metanálise em Rede , Propriedades de Superfície , Desgaste dos Dentes/etiologia , Zircônio/efeitos adversos , Ensaios Clínicos Controlados como Assunto
5.
J Vet Intern Med ; 38(1): 381-387, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37994487

RESUMO

BACKGROUND: Inhibition of hypoxia-inducible factor prolyl hydroxylase (HIF-PH) stimulates erythropoiesis in rats, dogs, monkeys, and humans. HYPOTHESIS/OBJECTIVE: Determine if molidustat, a novel HIF-PH inhibitor, stimulates erythropoiesis in healthy cats. ANIMALS: Seventeen healthy adult laboratory cats. METHODS: Randomized, placebo-controlled study. Cats were treated PO once daily with suspensions of 0 (Group 1; n = 6), 5 (Group 2; n = 6), or 10 (Group 3; n = 5) mg/kg of molidustat. Effects on red blood cell parameters, reticulocyte indices and plasma erythropoietin (EPO) concentrations were evaluated. Molidustat treatment was stopped when hematocrit (HCT) exceeded 60%. RESULTS: Compared to placebo, a significant increase in mean HCT was evident starting on Day 14 (Group 2:54.4% vs 40.3%, P < .001, 95% confidence interval [CI] for the difference [8.95-19.28]; Group 3:61.2% vs 40.3%, P < .001, 95% CI [15.48-26.43]) and remained significantly higher for the entire treatment period. In molidustat-treated groups, HCT exceeded 60% on Day 21 (Group 2) and Day 14 (Group 3). Mean HCT in molidustat-treated cats returned to within the reference range (29%-45%) after Day 56 and was numerically comparable to placebo from Day 70 onwards. Red blood cell count and hemoglobin concentrations followed a similar pattern as HCT. Mean EPO concentrations significantly increased after molidustat administration on all assessment days. Molidustat treatments were well tolerated. CONCLUSIONS AND CLINICAL IMPORTANCE: Marked erythropoietic effects were identified after daily administration of molidustat to healthy cats and additional studies are warranted to evaluate the effects in anemic cats.


Assuntos
Anemia , Doenças do Gato , Animais , Gatos , Anemia/veterinária , Doenças do Gato/tratamento farmacológico , Doenças do Gato/induzido quimicamente , Eritropoese , Pirazóis , Triazóis/farmacologia
6.
J Esthet Restor Dent ; 36(2): 391-401, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37680013

RESUMO

OBJECTIVE: To evaluate the flexural strength and fatigue behavior of a novel 3D-printed composite resin for definitive restorations. MATERIALS AND METHODS: Fifty disc-shaped specimens were manufactured from each of a nanohybrid composite resin (NHC), polymer-infiltrated ceramic network (PICN), and 3D-printed composite resin (3D) with CAD-CAM technology. Biaxial flexural strength (σin ) (n = 30 per group) and biaxial flexural fatigue strength (σff ) (n = 20 per group) were measured using piston-on-three-balls method, employing a staircase approach of 105 cycles. Weibull statistics, relative-strength degradation calculations, and fractography were performed. The results were analyzed with 1-way ANOVA and Games-Howell post hoc test (α = 0.05). RESULTS: Significant differences in σin and σff among the groups (p < 0.001) were detected. The NHC group provided the highest mean ± standard deviation σin and σff (237.3 ± 31.6 MPa and 141.3 ± 3.8 MPa), followed by the PICN (140.3 ± 12.9 MPa and 73.5 ± 9.9 MPa) and the 3D (83.6 ± 18.5 MPa and 37.4 ± 23.8 MPa) groups. The 3D group exhibited significantly lower Weibull modulus (m = 4.7) and up to 15% higher relative strength degradation with areas of nonhomogeneous microstructure as possible fracture origins. CONCLUSIONS: The 3D-printed composite resin exhibited the lowest mechanical properties, where areas of nonhomogeneous microstructure developed during the mixing procedure served as potential fracture origins. CLINICAL SIGNIFICANCE: The clinical indications of the investigated novel 3D-printed composite resin should be limited to long-term provisional restorations. A cautious procedure for mixing the components is crucial before the 3D-printing process, since nonhomogeneous areas developed during the mixing could act as fracture origins.


Assuntos
Cerâmica , Resinas Compostas , Resinas Compostas/química , Teste de Materiais , Cerâmica/química , Resistência à Flexão , Impressão Tridimensional , Desenho Assistido por Computador , Polímeros , Propriedades de Superfície
7.
Front Immunol ; 14: 1251593, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37965339

RESUMO

Introduction: Allogeneic stem cell transplantation is used to cure hematologic malignancies or deficiencies of the hematopoietic system. It is associated with severe immunodeficiency of the host early after transplant and therefore early reactivation of latent herpesviruses such as CMV and EBV within the first 100 days are frequent. Small studies and case series indicated that application of herpes virus specific T cells can control and prevent disease in this patient population. Methods: We report the results of a randomized controlled multi centre phase I/IIa study (MULTIVIR-01) using a newly developed T cell product with specificity for CMV and EBV derived from the allogeneic stem cell grafts used for transplantation. The study aimed at prevention and preemptive treatment of both viruses in patients after allogeneic stem cell transplantation targeting first infusion on day +30. Primary endpoints were acute transfusion reaction and acute-graft versus-host-disease after infusion of activated T cells. Results: Thirty-three patients were screened and 9 patients were treated with a total of 25 doses of the T cell product. We show that central manufacturing can be achieved successfully under study conditions and the product can be applied without major side effects. Overall survival, transplant related mortality, cumulative incidence of graft versus host disease and number of severe adverse events were not different between treatment and control groups. Expansion of CMV/EBV specific T cells was observed in a fraction of patients, but overall there was no difference in virus reactivation. Discussion: Our study results indicate peptide stimulated epitope specific T cells derived from stem cell grafts can be administered safely for prevention and preemptive treatment of reactivation without evidence for induction of acute graft versus host disease. Clinical trial registration: https://clinicaltrials.gov, identifier NCT02227641.


Assuntos
Infecções por Citomegalovirus , Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Humanos , Infecções por Citomegalovirus/prevenção & controle , Infecções por Citomegalovirus/complicações , Doença Enxerto-Hospedeiro/etiologia , Doença Enxerto-Hospedeiro/prevenção & controle , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/métodos , Herpesvirus Humano 4/fisiologia , Linfócitos T , Transplante Homólogo/efeitos adversos
8.
Int J Comput Dent ; 0(0): 0, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37823541

RESUMO

AIM: The adjustment and transfer of a stable occlusion can be a major challenge in prosthetic rehabilitations. The aim of this study was to assess a non-invasive treatment option for complex prosthetic rehabilitations and occlusal analyses using 3D-printed restorations clinically. MATERIALS AND METHODS: Eleven patients received a partial or complete rehabilitation with the aid of 3D-printed restorations (n=171). After 12 months of clinical service, all restorations were analyzed using the United States Public Health Service (USPHS) criteria. RESULTS: The 12-month clinical data revealed that 3D-printed restorations showed a survival rate of 84.4%. Complications occurred mostly regarding the anatomical form (7%) or marginal integrity (6AC%) and were consequently rated "Charlie" or "Delta." Color stability and color match of 3D-printed restorations were rated "Alpha" in 83% and 73%, respectively, of all restorations. Marginal inflammation was rated "Alpha" in 89% of all restorations. An excellent surface texture and no secondary caries or postoperative sensitivities (100%) were observed. CONCLUSIONS: 3D-printed restorations might be an alternative treatment option for initiating complex prosthetic rehabilitations. Technical complications rarely occurred. Biological complications did not occur at all. The color stability showed promising results after 12 months of clinical service. However, the results should be interpreted with caution. Long-term results with a high number of restorations should be awaited.

9.
Int J Implant Dent ; 9(1): 33, 2023 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-37730937

RESUMO

PURPOSE: Dental implant abutments are defined as medical devices by their intended use. Surfaces of custom-made CAD/CAM two-piece abutments may become contaminated during the manufacturing process in the dental lab. Inadequate reprocessing prior to patient care may contribute to implant-associated complications. Risk-adapted hygiene management is required to meet the requirements for medical devices. METHODS: A total of 49 CAD/CAM-manufactured zirconia copings were bonded to prefabricated titanium bases. One group was bonded, polished, and cleaned separately in dental laboratories throughout Germany (LA). Another group was left untreated (NC). Five groups received the following hygiene regimen: three-stage ultrasonic cleaning (CP and FP), steam (SC), argon-oxygen plasma (PL), and simple ultrasonic cleaning (UD). Contaminants were detected using scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) and segmented and quantified using interactive machine learning (ML) and thresholding (SW). The data were statistically analysed using non-parametric tests (Kruskal-Wallis test, Dunn's test). RESULTS: Significant differences in contamination levels with the different cleaning procedures were found (p ≤ 0.01). The FP-NC/LA groups showed the most significant difference in contamination levels for both measurement methods (ML, SW), followed by CP-LA/NC and UD-LA/NC for SW and CP-LA/NC and PL-LA/NC for ML (p ≤ 0.05). EDS revealed organic contamination in all specimens; traces of aluminum, silicon, and calcium were detected. CONCLUSIONS: Chemothermal cleaning methods based on ultrasound and argon-oxygen plasma effectively removed process-related contamination from zirconia surfaces. Machine learning is a promising assessment tool for quantifying and monitoring external contamination on zirconia abutments.


Assuntos
Implantes Dentários , Humanos , Argônio , Microscopia Eletrônica de Varredura , Aprendizado de Máquina , Oxigênio
10.
Int J Implant Dent ; 9(1): 34, 2023 09 21.
Artigo em Inglês | MEDLINE | ID: mdl-37733145

RESUMO

PURPOSE: This systematic review aimed to evaluate the incidence of microleakage events (IME) and to identify the potential factors influencing the sealing ability of the implant-abutment interface (IAI) under in vitro investigation. MATERIAL AND METHODS: An electronic search of MEDLINE (PubMed), EMBASE, and Web of Science databases, combined with a manual literature search was conducted up to September 2022. In vitro studies that reported the degree of microleakage at IAI under dynamic loading conditions were included. A meta-analysis was performed to calculate the mean values of the incidence of microleakage events. Subgroup analysis and meta-regression were conducted to further investigate the effect of different variables. RESULTS: 675 studies were identified following the search process and 17 in vitro studies were selected according to the eligibility criteria. The weighted mean incidence of microleakage events was 47% (95% confidence interval: [0.33, 0.60]), indicating that contamination was observed in nearly half of the samples. Concerning possible factors that may influence microleakage (e.g., loading condition, assessment method, implant-abutment connection design, types of abutment material, the use of sealing agents), loading condition (p = 0.016) was the only variable that significantly influenced IME in the meta-regression analysis. CONCLUSIONS: The results demonstrated that dynamic loading significantly increases the potential of bacterial penetration at the implant-abutment junction. The results should be interpreted carefully due to the data heterogeneity and further well-conducted in vitro studies with homogeneous samples are needed to standardize the methodologies.


Assuntos
Implantes Dentários , Bases de Dados Factuais , Contaminação de Medicamentos , Eletrônica , Definição da Elegibilidade
11.
Bioengineering (Basel) ; 10(9)2023 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-37760094

RESUMO

To date, no scientific data is available regarding the development and radiographic assessment of approximal caries development after the insertion of 3D-printed, non-invasive veneers of different restoration thicknesses. For the present study, non-invasive veneers were fabricated from two different materials for printing and milling (Vita Enamic and VarseoSmile Crown plus). Three different restoration thicknesses (0.5, 0.7, and 0.9 mm) were selected. After digital design, leaving the approximal space free, and manufacturing of the restorations, adhesive insertion followed. All specimens were placed in a demineralizing solution for 28 days. Subsequently, a radiological and fluorescent examination was performed. The present study showed statistically significant interactions for the day (p < 0.0001) and manufacturing method (p < 0.0001) but not for restoration thickness. Additive manufactured restorations showed less radiological caries progression compared to subtractive manufactured restorations after 21 and 28 days (0.7 and 0.9 mm restoration thickness) (p < 0.0001). DIAGNOdent proved that the restoration thickness affected the caries progression within the subtractive group (p < 0.0001). Radiographic and fluorescence examination showed equivalent results regarding approximal caries assessment. For additive manufacturing, less caries progression was shown without consideration of the restoration thickness.

12.
J Mech Behav Biomed Mater ; 146: 106085, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37625280

RESUMO

Material extrusion of thermoplastic polymers enables the realization of complex specific designs with high performance composites. The present study aims at evaluating the mechanical properties of carbon fiber-reinforced semi-crystalline thermoplastic polymer polyether ether ketone (CFR-PEEK) manufactured by material extrusion and correlating them with results obtained by micro-CT. Samples in the shape of small bars were provided by Kumovis (Munich, Germany). The determination of surface roughness and density was followed by three-point bending tests. To reveal the pore distribution as well as the fusion quality of CFR PEEK when applied with external forces, micro-CT scans were performed with an X-ray microscope before and after the mechanical test to localize the sites where the fracture is generated. The density of CFR-PEEK bars indicated that they had superior mechanical properties compared with our previous study on unfilled 3D printed PEEK (bending modulus: (5.4 ± 0.5) GPa vs. (1.05 ± 0.05) GPa to (1.48 ± 0.10) GPa; bending strength: (167 ± 11) MPa vs. (51 ± 15) to (193 ± 7) MPa). Micro-CT analyses revealed the local 3D-distribution of voids. Voids of 30 µm diameter are nearly spherical and make up the main part of the total porosity. The larger the voids, the more they deviate from a spherical shape. Significant lack-of-fusion voids are located between the deposited filaments. By growing and merging, they act as seeds for the forming fracture line in the region of the flexural specimens where the maximum local tensile stresses occurred under bending load. Our work provides a detailed analysis of printed PEEK with fiber additive and relates this with mechanical properties.


Assuntos
Benzofenonas , Fraturas Ósseas , Humanos , Microtomografia por Raio-X , Fibra de Carbono , Cetonas , Plásticos , Polietilenoglicóis
14.
Acta Neurol Belg ; 123(6): 2111-2114, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37121932

RESUMO

PURPOSE: The purpose of this mini review is to describe metabolomics in cerebrospinal fluid (CSF) and its potential in aneurysmal subarachnoid hemorrhage (aSAH). In brain injury, patients' micro dialysis enables detecting biochemical change in brain tissue. Indicators for ischemia were detected such as lactate, pyruvate, glucose, and glutamate. In aSAH patients, the pathophysiology and the factor for poor outcome are not completely understood yet. Routine use of biomarkers in CSF, particularly in aSAH patients, is still lacking. METHODS: This mini review was performed on the role of metabolomics alterations after aneurysmal subarachnoid hemorrhage. RESULTS: We identified five clinical studies that addressed metabolomics in patients with aneurysmal subarachnoid hemorrhage. CONCLUSION: There is increasing evidence suggesting that biomarkers can give insight in the pathogenesis and can serve as an outcome predictor. In this mini review, we present a brief overview of metabolomics profiling in neuroscience and wish to discuss the predictive and therapeutic value in aSAH patients.


Assuntos
Isquemia Encefálica , Hemorragia Subaracnóidea , Humanos , Hemorragia Subaracnóidea/complicações , Biomarcadores/líquido cefalorraquidiano , Isquemia Encefálica/diagnóstico , Ácido Láctico , Ácido Pirúvico
15.
Data Brief ; 48: 109062, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37006387

RESUMO

This dataset is related to the research paper entitled "Bridge-specific flood risk assessment of transport networks using GIS and remotely sensed data" published in the Science of the Total Environment. It provides the information necessary for the reproduction of the case study that was used for the demonstration and validation of the proposed risk assessment framework. The latter integrates indicators for the assessment of hydraulic hazards and bridge vulnerability with a simple and operationally flexible protocol for the interpretation of bridge damage consequences on the serviceability of the transport network and on the affected socio-economic environment. The dataset encompasses (i) inventory data for the 117 bridges of the Karditsa Prefecture, in Central Greece, which were affected by a historic flood that followed the Mediterranean Hurricane (Medicane) Ianos, in September 2020; (ii) results of the risk assessment analysis, including the geospatial distribution of hazard, vulnerability, bridge damage, and associated consequences for the area's transport network; (iii) an extensive damage inspection record, compiled shortly after the Medicane, involving a sample of 16 (out of the 117) bridges of varying characteristics and damage levels, ranging from minimal damage to complete failure, which was used as a reference for validation of the proposed framework. The dataset is complemented by photos of the inspected bridges which facilitate the understanding of the observed bridge damage patterns. This information is intended to provide insights into the response of riverine bridges to severe floods and a thorough base for comparison and validation of flood hazard and risk mapping tools, potentially useful for engineers, asset managers, network operators and stakeholders involved in decision-making for climate adaptation of the road sector.

16.
Cell Host Microbe ; 31(3): 373-388.e10, 2023 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-36893734

RESUMO

The decision whether endosomes enter the degradative or recycling pathway in mammalian cells is of fundamental importance for pathogen killing, and its malfunctioning has pathological consequences. We discovered that human p11 is a critical factor for this decision. The HscA protein present on the conidial surface of the human-pathogenic fungus Aspergillus fumigatus anchors p11 on conidia-containing phagosomes (PSs), excludes the PS maturation mediator Rab7, and triggers binding of exocytosis mediators Rab11 and Sec15. This reprogramming redirects PSs to the non-degradative pathway, allowing A. fumigatus to escape cells by outgrowth and expulsion as well as transfer of conidia between cells. The clinical relevance is supported by the identification of a single nucleotide polymorphism in the non-coding region of the S100A10 (p11) gene that affects mRNA and protein expression in response to A. fumigatus and is associated with protection against invasive pulmonary aspergillosis. These findings reveal the role of p11 in mediating fungal PS evasion.


Assuntos
Aspergillus fumigatus , Fagossomos , Animais , Humanos , Aspergillus fumigatus/genética , Aspergillus fumigatus/metabolismo , Endossomos , Esporos Fúngicos , Mamíferos
17.
J Prosthodont Res ; 67(4): 562-567, 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-36804247

RESUMO

PURPOSE: To investigate the effects of printing-layer thickness and build angle on the surface characteristics and microbial adhesion of denture base polymers manufactured by digital light processing (DLP). METHODS: Specimens were additively manufactured using DLP. The specimens were printed with different printing-layer thicknesses (25, 50, and 100 µm) and build angles (0°, 45°, and 90°). Scanning electron microscopy was used to observe the surface topography, and the arithmetical mean heights (Sa) were measured. Moreover, the initial Candida albicans (C. albicans) adhesion to the specimens was evaluated using an adhesion test. Finally, two-way ANOVA and Tukey's multiple comparison tests were conducted. RESULTS: The results regarding the Sa values exhibited a statistically significant interaction (F (4, 45) = 90.77, P < 0.0001). The build angle has a significant impact on the surface topography. Furthermore, quantitative results revealed that the printing-layer thickness significantly affected C. albicans adhesion (F (2, 99) = 6.96, P = 0.0015). CONCLUSIONS: The surface roughness was significantly affected by the printing-layer thickness and the build angle. Additionally, the surface topography was mainly determined by the build angle. Furthermore, the adhesion of C. albicans to the DLP-printed denture surfaces was significantly affected by the printing-layer thickness but not by the build angle. Consequently, it is critical to decrease the thickness of the printing layer to produce digital dentures with optimal material properties.

18.
Int J Comput Dent ; 0(0): 0, 2023 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-36811290

RESUMO

PURPOSE: A reference method for quantifying contaminations on two-piece abutments manufactured using CAD/CAM (Computer-Aided Design/Computer-Aided Manufacturing) has not yet been established. In this in vitro study, a pixel-based machine learning method for detecting contamination on customised two-piece abutments was investigated and embedded in a semi-automated quantification pipeline. MATERIAL AND METHODS: Forty-nine CAD/CAM zirconia abutments were fabricated and bonded to a prefabricated titanium base. All samples were analysed for contamination by scanning electron microscopy (SEM) imaging followed by pixel-based machine learning (ML) and thresholding (SW) for contamination detection; quantification was performed in the post-processing pipeline. Wilcoxon signed-rank test and Bland-Altmann plot were applied to compare both methods. The contaminated area fraction was recorded as a percentage. RESULTS: There was no statistically significant difference between the percentages of contamination areas (median = 0.004) measured with ML (median = 0.008) and with SW (median = 0.012), asymptotic Wilcoxon-test: p = 0.22. The Bland-Altmann plot demonstrated a mean difference of -0,006% (95% confidence interval, CI from -0.011% to 0.0001%) with increased values from a contamination area fraction > 0.03% for ML. CONCLUSION: Both segmentation methods showed comparable results in evaluating surface cleanliness; pixel based machine learning is a promising assessment tool for detecting external contaminations on zirconia abutments; Further studies must investigate its clinical performance.

19.
mSphere ; 8(1): e0052322, 2023 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-36719247

RESUMO

Alveolar macrophages belong to the first line of defense against inhaled conidia of the human-pathogenic fungus Aspergillus fumigatus. In lung alveoli, they contribute to phagocytosis and elimination of conidia. As a counterdefense, conidia have a gray-green pigment that enables them to survive in phagosomes of macrophages for some time. Previously, we showed that this conidial pigment interferes with the formation of flotillin-dependent lipid raft microdomains in the phagosomal membrane, thereby preventing the formation of functional phagolysosomes. Besides flotillins, stomatin is a major component of lipid rafts and can be targeted to the membrane. However, only limited information on stomatin is available, in particular on its role in defense against pathogens. To determine the function of this integral membrane protein, a stomatin-deficient macrophage line was generated by CRISPR/Cas9 gene editing. Immunofluorescence microscopy and flow cytometry revealed that stomatin contributes to the phagocytosis of conidia and is important for recruitment of the ß-glucan receptor dectin-1 to both the cytoplasmic membrane and phagosomal membrane. In stomatin knockout cells, fusion of phagosomes and lysosomes, recruitment of the vATPase to phagosomes, and tumor necrosis factor alpha (TNF-α) levels were reduced when cells were infected with pigmentless conidia. Thus, our data suggest that stomatin is involved in maturation of phagosomes via fostering fusion of phagosomes with lysosomes. IMPORTANCE Stomatin is an integral membrane protein that contributes to the uptake of microbes, e.g., spores of the human-pathogenic fungus Aspergillus fumigatus. By generation of a stomatin-deficient macrophage line by advanced genetic engineering, we found that stomatin is involved in the recruitment of the ß-glucan receptor dectin-1 to the phagosomal membrane of macrophages. Furthermore, stomatin is involved in maturation of phagosomes via fostering fusion of phagosomes with lysosomes. The data provide new insights on the important role of stomatin in the immune response against human-pathogenic fungi.


Assuntos
Aspergillus fumigatus , Macrófagos , Humanos , Aspergillus fumigatus/metabolismo , Macrófagos/microbiologia , Fagossomos , Proteínas de Membrana/metabolismo , Microdomínios da Membrana/metabolismo
20.
World Neurosurg ; 170: 163-173.e1, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36372321

RESUMO

OBJECTIVE: Lumbar disc herniation (LDH) is a global issue associated with potentially debilitating long-term consequences, including chronic low back pain (LBP). Short-term outcomes (<2 years) of patients with LDH have been extensively studied and demonstrate improvements in back and leg pain for both operative and conservative management. However, these improvements may not be sustained long-term (>2 years); patients with LDH may develop recurrent disc herniations, progressive degenerative disc disease, and LBP regardless of management strategy. Therefore, our objective is to determine the prevalence of chronic LBP after LDH, understand the relationship between LDH and chronic LBP, and investigate the relationship between radiological findings and postoperative pain outcomes. METHODS: We performed a literature review on the PubMed database via a combination medical subject heading and keyword-based approach for long-term LBP outcomes in patients with LDH. RESULTS: Fifteen studies (2019 patients) evaluated surgical and/or nonoperative outcomes of patients with LDH . Regardless of surgical or nonoperative management, 46.2% of patients with LDH experienced some degree of LBP long-term (range 2-27 years) as compared to a point prevalence of LBP in the general population of only 11.9%. CONCLUSIONS: Patients with LDH are more likely to experience long-term LBP compared to the general population (46.2% vs. 11.9%). Additionally, understanding the relationship between radiological findings and pain outcomes remains a major challenge as the presence of radiological changes and the degree of LBP do not always correlate. Therefore, higher quality studies are needed to better understand the relationship between radiological findings and pain outcomes.


Assuntos
Deslocamento do Disco Intervertebral , Dor Lombar , Humanos , Deslocamento do Disco Intervertebral/complicações , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/epidemiologia , Dor Lombar/diagnóstico por imagem , Dor Lombar/epidemiologia , Dor Lombar/etiologia , Prevalência , Resultado do Tratamento , Dor Pós-Operatória/etiologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Discotomia/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...